Talk To Us About Enforcer

Early Detection System

Fire Rover’s Early Detection System combines thermal, flame, and smoke analytics to identify fire risks before they spread, enabling rapid response and protecting high-risk environments around the clock.

Continuous Suppression System

An automated, large-scale protection solution that detects, verifies, and suppresses fires in seconds — providing constant coverage for operations that can’t afford downtime.

Self-Contained Suppression System

A compact, all-in-one system designed for standalone fire protection, ideal for targeted coverage in smaller or remote areas without existing infrastructure.

OnWatch Mobile Detection System

A flexible, camera-based monitoring system that brings real-time thermal detection and human verification anywhere it’s needed — ideal for temporary sites or expanding operations.

Mobile Suppression Unit System

Fire Rover’s fully mobile suppression system combines advanced detection, onboard agent storage, and remote operation to deliver rapid response and protection wherever the risk is.

Enforcer Suppression Unit

Enforcer provides scalable, mobile suppression for industrial environments where speed and flexibility matter most.

Waste and Recycling

Open air, shifting materials, and limited infrastructure make landfills especially vulnerable to incipient fires. Fire Rover provides rapid mobile detection with 24/7 thermal monitoring and video-verified alerting — delivering protection where permanent systems can’t reach.

Marine

Sparks, welding equipment, and combustible materials are common in shipyards and other marine situations. Our Mobile Suppression System quickly delivers high-volume suppression directly to the ignition source — all while keeping your crew at a safe distance.

Metal Processing

From hot loads to lithium battery ignitions, scrapyards face unpredictable fire risks. Our hybrid approach combines mobile detection, continuous suppression, and site-specific strategies to stay ahead of threats in even the harshest environments, whether indoors or outdoors.

Wood Processing

Dust, organic material, and high heat combine to make these facilities a fire hazard. Fire Rover’s integrated detection and suppression systems provide persistent monitoring and immediate suppression to prevent deep-seated fires in bulk storage or conveyor lines.

Portable Fire Suppression
Built for Rapid Deployment

The Fire Rover Enforcer® is a high-performance, portable fire suppression unit designed to deliver fast, targeted protection in high-risk environments without the need for a water connection.

Fire Suppression
That Adapts to the Risk

Every fire risk presents different challenges. The Fire Rover Enforcer product line delivers flexible, high-performance suppression options that scale from immediate response to large-capacity control — giving facilities the ability to respond faster, smarter, and with pinpoint precision.

Freeze Protection

Operates in extreme cold without performance loss. Foam stays ready down to -40°F for year-round protection.

No Water Connection

Completely mobile suppression with no fixed water supply required. Deploy quickly wherever fire risk appears.

Spray Range

Reach fire threats from a safe distance. The Enforcer delivers powerful suppression coverage 150+ feet away.

Easily Refillable

Recharge and redeploy quickly. Simply replace the nitrogen cylinder and refill with FireBull and water to restore protection.

Enforcer® Air 3

Ultra-portable suppression for immediate response in tight or mobile environments.

Enforcer<sup>®</sup> Air 3

Features

  • Pressure Vessel Capacity: 3 U.S. Gallons
  • Finished Foam Capacity: 60 U.S. Gallons
  • Operating Pressure: 100–125 PSI
  • Maximum Pressure: 125 PSI
  • Fill Valve: Schraeder
  • Discharge Control: Easy On/Off Thumb Wheel

Performance

  • Throw Distance: Up to 30 Feet
  • Discharge Duration: Up to 1 Minute
  • Coverage Area: Up to 600 sq ft

Fire Class Applications:

  • Class A
  • Class B
  • Class D
  • Class K

Physical Properties

  • Height: 24.25"
  • Width: 14.5"
  • Length: 7.25"
  • Empty Weight: 18 lbs
  • Loaded Weight: 44 lbs
  • Mix Tank Capacity: 3 gallons
  • Finished Foam Output: 60 gallons

Application Notes

  • Mounting Bracket
  • Shoulder Strap
  • Backpack

Certifications

  • NTA 8133:2021
  • Li-Ion Lithium Battery Fire Suppression Standard

Enforcer® 10

Lightweight rapid knockdown for early-stage incidents and support teams.

Enforcer<sup>®</sup> 10

Features

  • Pressure Vessel Construction: Aluminum SAE J-10
  • System Hoses: 3000 PSI Hard Rubber Hose
  • Discharge Hose: 100 Foot ½” Hose
  • Hose Storage: Manual Hose Reel
  • Propellant Type: Nitrogen or Compressed Air
  • Discharge Nozzle: Pistol Grip
  • Discharge Nozzle Tip: Straight Bore

Performance

  • Pressure Vessel Capacity: 10 U.S. Gallons
  • Finished Foam Capacity: Up to 200 U.S. Gallons
  • Throw Distance: Up to 45 Feet
  • Discharge Duration: Up to 2½ Minutes
  • Coverage Area: Up to 2,000 sq ft

Physical Properties

  • Height: 23.5”
  • Width: 24.5”
  • Length: 26”
  • Empty Weight: 90 Pounds
  • Loaded Weight: 187 Pounds

Application Notes

  • Additional Nitrogen Cylinders
  • Protective Cover
  • Nitrogen to Compressed Air Adapter
  • Wagon Pull Cart
  • Available in 4500 SCBA Configuration

Certifications

  • UL 711 20:B

Enforcer® 60

High-output suppression for demanding industrial and municipal applications.

Enforcer<sup>®</sup> 60

Features

  • Pressure Vessel Construction: Aluminum SAE J-10
  • System Hoses: 3000 PSI Hard Rubber Hose
  • Discharge Hose: Extended Industrial Hose Configuration
  • Propellant Type: Nitrogen or Compressed Air
  • Discharge Nozzle: Pistol Grip
  • Discharge Nozzle Tip: Straight Bore
  • Mounting Options: Skid or Caster Configuration

Performance

  • Pressure Vessel Capacity: 60 U.S. Gallons
  • Finished Foam Capacity: Up to 1,200 U.S. Gallons
  • Throw Distance: Up to 95 Feet
  • Discharge Duration: Up to 6 Minutes
  • Coverage Area: Up to 13,000 sq ft

Physical Properties

  • Height as Skid: 30.5”
  • Height with Casters: 59.5”
  • Width: 28.5”
  • Length: 48”
  • Empty Weight: 475 Pounds
  • Loaded Weight: 975 Pounds

Application Notes

  • Additional Nitrogen Cylinders
  • Additional Hose Options
  • Protective Cover

Enforcer® 200

Maximum-capacity control for large sites, extended incidents, and fleet deployment.

Enforcer<sup>®</sup> 200

Features

  • Pressure Vessel Construction: Aluminum SAE J-10
  • System Hoses: Heavy-Duty Industrial Hose Configuration
  • Propellant Type: Nitrogen or Compressed Air
  • Discharge Nozzle: Pistol Grip
  • Discharge Nozzle Tip: Straight Bore
  • Mounting Options: Truck, Trailer, or Cart Upgrade

Performance

  • Pressure Vessel Capacity: 200 U.S. Gallons
  • Finished Foam Capacity: Up to 4,000 U.S. Gallons Finished Foam
  • Throw Distance (1” Line): Up to 95 Feet
  • Throw Distance (1½” Line): Up to 120 Feet
  • Discharge Duration: Up to 20 Minutes
  • Coverage Area: Up to 40,000 sq ft

Physical Properties

  • Height: 45”
  • Width: 44”
  • Length: 98”
  • Empty Weight: 1,200 Pounds
  • Loaded Weight: 2,800 Pounds

Application Notes

  • Additional Nitrogen or Air Cylinders
  • Additional Hose Options
  • Protective Cover
  • Cart Option Upgrade

Suppression Solutions
Built to Scale

The Enforcer product line offers multiple suppression options, allowing facilities to match response capability to risk, environment, and operational needs.

Enforcer Air 3
Enforcer 10
Enforcer 60
Enforcer 200
Features
Enforcer Air 3
Enforcer 10
Enforcer 60
Enforcer 200
Primary Use
3 U.S. Gallons
10 U.S. Gallons
60 U.S. Gallons
200 U.S. Gallons
Typical Mounting
Up to 60 U.S. Gallons
Up to 200 U.S. Gallons
Up to 1,200 U.S. Gallons
Up to 4,000 U.S. Gallons Finished Foam
Foam Capacity
Up to 30 Feet
Up to 45 Feet
Up to 95 Feet
1” Line: Up to 95 Feet
1½” Line: Up to 120 Feet
Ideal Environments
Up to 1 Minute
Up to 2½ Minutes
Up to 6 Minutes
Up to 20 Minutes
Role in Fire Rover
Up to 600 sq ft
Up to 2,000 sq ft
Up to 13,000 sq ft
Up to 40,000 sq ft

Engineered for Rapid Response
and Real-World Conditions

Superior CAFS Performance

Compressed Air Foam delivers rapid knockdown, increased surface cooling, and expanded coverage while reducing overall water usage.

Enhances Fire Rover Systems

Complements Fire Rover’s remote detection and monitoring solutions with on-the-ground suppression capability.

Frequently Asked Questions

Can I use my Enforcer® CAFS unit more than once?

Yes, it can be used many times during the unit's lifetime. After use, all that is necessary is to replace the nitrogen gas cylinder (refilled or exchanged at nearby welding supply) and add the proper percentage of FireAde and Water.

Do Enforcer Compressed Air Foam System (CAFS) units need electricity?

No. Enforcer CAFS are powered by compressed air or nitrogen gas.

What maintenance does Enforcer CAFS require?

Little or no maintenance is required for the lifetime of the unit, providing reasonable care is taken to protect the unit from freezing and it is shielded from the sun. It is necessary to check the pressure level in the nitrogen gas cylinder at least once a year.

What types of fires is the Enforcer designed to handle?

The Enforcer line is designed for early-stage industrial fire scenarios such as hot loads, equipment fires, fuel-related incidents, and material fires that can escalate quickly. Its compressed air foam technology is especially effective in environments where rapid knockdown and surface cooling are critical to preventing fire spread.

How does the Enforcer compare to traditional water-based firefighting methods?

The Enforcer uses compressed air foam to deliver faster knockdown and improved heat absorption while using significantly less water than traditional suppression methods. This makes it particularly effective in industrial, outdoor, or water-limited environments where water alone may be insufficient.

Is the Enforcer intended to replace fixed fire suppression systems?

No. The Enforcer is designed to complement fixed systems like sprinklers by providing a mobile, rapidly deployable suppression option. It’s especially useful in areas where fixed infrastructure is limited, impractical, or too slow to respond to emerging fire risks.

Can the Enforcer be used in remote or water-limited locations?

Yes. The Enforcer’s foam technology allows it to produce significantly more finished firefighting foam than its water capacity alone, making it well suited for remote sites, mobile operations, and facilities with limited water access.

How do I choose the right Enforcer model for my facility?

Choosing the right Enforcer model depends on factors like facility size, fire risk level, available water supply, and how the unit will be deployed. Fire Rover works with customers to evaluate these variables and recommend the Enforcer configuration that best fits their operational needs.

Can the Enforcer operate in extremely cold climates?

Yes. The Enforcer is designed for year-round industrial use, including cold-weather environments. Its freeze-protected foam formulation remains effective down to -40°F, making it a reliable suppression option for facilities in northern climates where traditional water-based systems may be limited.

Want to
Talk to Us?
Get in Touch.

Contact Us
Phone: (248) 671-6899
Email: info@firerover.com

Headquarters
24505 Indoplex Circle
Farmington Hills, MI 48335

Sales and Administration
6960 Orchard Lake Road, Suite 303
West Bloomfield, MI 48322

Please fill out the form below.

This field is for validation purposes and should be left unchanged.
This field is hidden when viewing the form
This field is hidden when viewing the form
This field is hidden when viewing the form
This field is hidden when viewing the form
This field is hidden when viewing the form
This field is hidden when viewing the form
This field is hidden when viewing the form

Download The
Pricing Guide

Contact Us
Phone: (248) 671-6899
Email: info@firerover.com

Headquarters
24505 Indoplex Circle
Farmington Hills, MI 48335

Sales and Administration
6960 Orchard Lake Road, Suite 303
West Bloomfield, MI 48322

Please fill out the form below.

This field is for validation purposes and should be left unchanged.
This field is hidden when viewing the form
This field is hidden when viewing the form
This field is hidden when viewing the form
This field is hidden when viewing the form
This field is hidden when viewing the form
This field is hidden when viewing the form
This field is hidden when viewing the form